Engineering
.
open

HV Electrical Engineer

Engineering

Own primary design from single-line diagram to energisation.

Wacol, Brisbane

Site visits to Richlands, Ipswich, Brendale and Yatala.

Full-time, permanent

$135,000 to $165,000 plus 12% super.

Mid to senior, 5 to 10 years

We test whether the candidate can own earthing and cable design to AS 2067 without a second engineer redoing it, and has an RPEQ path.

Design the primary systems that switch on Queensland's data centres. At Kestrel Power you will size HV cables, calculate earthing to ENA EG-1 and take 11 kV to 132 kV substations from single-line diagram to energisation. You sit in every design review, witness factory acceptance tests and answer site questions within 24 hours. $135,000 to $165,000 plus super. Wacol, Brisbane.

Purpose
  1. The HV Electrical Engineer designs and checks the primary electrical systems of Kestrel's substations and switchyards, from single-line diagrams to earthing and cable sizing. You hold each design to the network's requirements and to AS 2067 so the energisation date never moves for a design reason. You are the technical authority on primary plant for every project you touch.
Responsibilities
  1. Produce and review single-line diagrams, general arrangements, load flow and fault level calculations for 11 kV to 132 kV substations.
  2. Design earth grids and calculate touch, step and transferred potentials to ENA EG-1 and AS 2067.
  3. Size and specify HV cables, terminations and support systems to AS/NZS 3008.1.1 and manufacturer ratings.
  4. Specify and technically evaluate transformers, switchgear, neutral earthing resistors and surge arresters for bids and procurement.
  5. Run design reviews at 30%, 60% and 100% with the client's designer and the network connection engineer, closing comments within 10 business days.
  6. Prepare network design submissions and respond to Network Service Provider queries.
  7. Answer site requests for information within 24 hours and attend site for first-of-type installations.
  8. Review factory acceptance test plans and witness acceptance tests for transformers and switchgear.
  9. Issue design-for-construction packages and check red-line as-builts at handover.
  10. Support estimating on bids above $5 million with quantities, design risks and a stated design basis.
Essential criteria
  1. Bachelor of Engineering (Electrical or Power) from an Engineers Australia accredited program.
  2. Five or more years designing HV substations or switchyards at 11 kV to 132 kV.
  3. Registered Professional Engineer of Queensland (RPEQ), or eligible and able to register within six months of starting.
  4. Working knowledge of AS 2067 and ENA EG-1, with earthing software experience (CDEGS or SES).
  5. Fault level and load flow modelling in DIgSILENT PowerFactory or ETAP.
  6. White card (Construction Induction) and a Queensland C-class driver licence.
  7. Holds, or will obtain within 30 days of starting, an ESI worker card.
  8. Permanent Australian work rights.
Desirable criteria
  1. Data centre power design experience (N+1 and 2N architectures).
  2. Powerlink or Energex connection process experience.
  3. 66 kV to 132 kV GIS design or installation experience.
  4. Working knowledge of IEC 61850 architecture.
  5. Revit or 3D model coordination experience.
First 90 days
  1. Days 1 to 30: complete safety induction and ESI induction, review three live design packages, take ownership of earthing design on the first data centre project.
  2. Days 31 to 60: lead the first 60% design review, issue the first network design submission.
  3. Days 61 to 90: issue the first design-for-construction package, witness a factory acceptance test, hold a 24-hour RFI response record.
Success measures
  1. At least 95% of design packages issued on the planned date.
  2. At least 80% of network submissions accepted at first review.
  3. At least 90% of site RFIs answered within 24 hours, with no design-caused delay above one day.
Screening questions
  1. State the highest voltage and largest MVA substation you designed through to energisation, and your role in it.
  2. Describe an earthing design where touch voltage failed the first calculation. What did you change?
  3. Which Queensland network connection process have you worked through, and what was the longest approval delay?
  4. Do you hold RPEQ? If not, what is your registration pathway and expected date?
  5. Describe a site RFI that exposed a design error. What did you do in the first 24 hours?
Package and conditions
  1. Reports to: Head of Engineering.
  2. Salary band: $135,000 to $165,000 plus 12% superannuation.
  3. Award: Professional Employees Award MA000065, engineering classification Level 3 to Level 4 benchmark; paid above award.
  4. Location and roster: Wacol depot with site visits to Richlands, Ipswich, Brendale and Yatala. Monday to Friday, 38 hours, one work-from-home day after probation.
  5. Employment type: Permanent, full-time.
  6. How to apply: use the Apply button to open the Kestrel careers portal, answer the five screening questions and attach your CV and tickets. Questions go to careers@thekestrelpower.com. Kestrel Power starts trading on 4 January 2027; start dates are agreed with each successful candidate.
open role

HV Electrical Engineer

reports to
Head of Engineering
location
Wacol, Brisbane
type
Full-time, permanent
band
$135k – $165k
super
12% on top
Electrical workers inspecting switchgear panels in a dimly lit workshop.